184PIN DDR400 Unbuffered DIMM
1024MB With 64Mx8 CL3
Transcend Information Inc.
6
(Recommended operating condition unless otherwise noted, TA = 0 to 70°C)
Parameter Symbol Max. Unit Note
Operating current - One bank Active-Precharge;
tRC=tRCmin; tCK= tCK min
DQ, DM and DQS inputs changing twice per clock cycle;
Address and control inputs changing once per clock cycle
IDD0 1,280 mA
Operating current - One bank Active-Read-Precharge; Burst=2;
tRC=tRC min; CL=2.5; tCK=tCK min; VIN=VREF fro DQ,DQS and DM
IDD1 1,520 mA
Percharge power-down standby current; All banks idle; power –
down mode; CKE = <VIL(max); tCK= tCK min
VIN = VREF
for DQ,DQS and DM
IDD2P 80 mA
Precharge Floating standby current; CS# > =VIH(min);All banks idle;
CKE > = VIH(min); tCK=166Mhz for DDR333
Address and other control inputs changing once per clock cycle;
VIN = VREF for DQ,DQS and DM
IDD2F 880 mA
Active power - down standby current ; one bank active; power-down mode; CKE<=
VIL (max); tCK = tCK min;
VIN = VREF for DQ,DQS and DM
IDD3P 720 mA
Active standby current; CS# >= VIH(min); CKE>=VIH(min);
one bank active; active - precharge; tRC=tRASmax; tCK = tCK min;
DQ, DQS and DM inputs changing twice per clock cycle; address and other control
inputs changing once per clock cycle
IDD3N 960 mA
Operating current - burst read; Burst length = 2; reads; continuous burst; One bank
active; address and control inputs changing once per clock cycle; CL=2.5 at tCK =
tCK min ; 50% of data changing at every burst; lout = 0 mA
IDD4R 1,560 mA
Operating current - burst write; Burst length = 2; writes; continuous burst; One bank
active address and control inputs changing once per clock cycle; CL=2.5 at tCK =
tCK min ; DQ, DM and DQS inputs changing twice per clock cycle, 50% of input
data changing at every burst
IDD4W 1,560 mA
Auto refresh current; tRC = tRFC(min) IDD5 5,520 mA
Self refresh current; CKE <= 0.2V; IDD6 80 mA
Operating current - Four bank operation;
Four bank interleaving with BL=4
-Refer to the following page for detailed test condition
IDD7 3,640 mA
Note: Module IDD was calculated on the basis of component IDD and can be differently measured according to DQ
loading cap.
AC OPERATING CONDITIONS
Parameter Symbol Min Max Unit
Komentarze do niniejszej Instrukcji