200PIN DDR2 400 SO-DIMM
512MB With 64Mx8 CL3
Transcend Information Inc.
6
IDD Specification parameters Definition
( IDD values are for full operating range of voltage and Temperature)
Parameter Symbol Max. Unit Note
Operating One bank Active-Precharge current; tCK = tCK(IDD), tRC = tRC(IDD),
tRAS = tRASmin(IDD); CKE is HIGH, CS\ is HIGH between valid commands;
Address bus inputs are SWITCHING; Data bus inputs are SWITCHING
IDD0 800 mA
Operating One bank Active-read-Precharge current; IOUT = 0mA; BL = 4, CL =
CL(IDD), AL = 0; tCK = tCK(IDD), tRC = tRC (IDD), tRAS = tRASmin(IDD), tRCD =
tRCD(IDD); CKE is HIGH, CS\ is HIGH between valid commands; Address bus
inputs are SWITCHING; Data pattern is same as IDD4W
IDD1 880 mA
Precharge power-down current; All banks idle; tCK = tCK(IDD); CKE is LOW;
Other control and address bus inputs are STABLE; Data bus inputs are FLOATING
IDD2P 64 mA
Precharge quiet standby current; All banks idle; tCK = tCK(IDD); CKE is HIGH,
CS\ is HIGH; Other control and address bus inputs are STABLE; Data bus inputs are
FLOATING
IDD2Q 200 mA
Precharge standby current; All banks idle; tCK = tCK(IDD); CKE is HIGH, CS\ is
HIGH; Other control and address bus inputs are SWITCHING; Data bus inputs are
SWITCHING
IDD2N 240 mA
Fast PDN Exit MRS(12) = 0mA
IDD3P-F 240
Active power - down current; All banks open; tCK
= tCK(IDD); CKE is LOW; Other control and address
bus inputs are STABLE; Data bus inputs are
FLOATING
Slow PDN Exit MRS(12) = 1mA IDD3P-S 120
mA
Active standby current; All banks open; tCK = tCK(IDD), tRAS = tRASmax(IDD),
tRP = tRP(IDD); CKE is HIGH, CS\ is HIGH between valid commands; Other control
and address bus inputs are SWITCHING; Data bus inputs are SWITCHING
IDD3N 560 mA
Operating burst read current; All banks open, Continuous burst reads, IOUT =
0mA; BL = 4, CL = CL(IDD), AL = 0; tCK = tCK(IDD), tRAS = tRASmax(IDD), tRP =
tRP(IDD); CKE is HIGH, CS\ is HIGH between valid commands; Address bus inputs
are SWITCHING; Data pattern is same as IDD4W
IDD4R 1,440 mA
Operating burst write current; All banks open, Continuous burst writes; BL = 4, CL
= CL(IDD), AL = 0; tCK = tCK(IDD), tRAS = tRASmax(IDD), tRP = tRP(IDD); CKE is
HIGH, CS\ is HIGH between valid commands; Address bus inputs are SWITCHING;
Data bus inputs are SWITCHING IDD4R
IDD4W 1,600 mA
Burst Auto refresh current; tCK = tCK(IDD); Refresh command at every tRFC(IDD)
interval; CKE is HIGH, CS\ is HIGH between valid commands; Other control and
address bus inputs are SWITCHING; Data bus inputs are SWITCHING
IDD5B 1,560 mA
Self refresh current; CK and CK\ at 0V; CKE 0.2V; Other control and address
bus inputs are FLOATING; Data bus inputs are FLOATING
IDD6 44 mA
Operating bank interleave read current; All bank interleaving reads, IOUT = 0mA;
BL = 4, CL = CL(IDD), AL = tRCD(IDD)-1*tCK(IDD); tCK =tCK(IDD), tRC = tRC(IDD),
tRRD = tRRD(IDD), tRCD = 1*tCK(IDD); CKE is HIGH, CS\ is HIGH between valid
commands; Address bus inputs are STABLE during Deselects; Data pattern is same
as IDD4R; Refer to the following page for detailed timing conditions
IDD7 2,200 mA
Note: 1. Module IDD was calculated on the basis of component IDD and can be differently measured according to DQ
loading capacitor.
Przeglądanie stron 5
1 2 3 4 5 6 7 8 9 10 11

Komentarze do niniejszej Instrukcji

Brak uwag

Powerplus POWXG9442 GAR DEN PUMP 800W DE manuales

Manuales del propietario y guías del usuario para Zapatillas Powerplus POWXG9442 GAR DEN PUMP 800W DE.
Ofrecemos 1 manuales en pdf Powerplus POWXG9442 GAR DEN PUMP 800W DE para descargar gratis por tipos de documentos: Manual de usuario






Más productos y manuales para Zapatillas Powerplus

Modelos Tipo de documento
POWXG9447 GAR DEN PUMP 1200W SS DE Manual de usuario   Powerplus POWXG9447 GAR DEN PUMP 1200W SS DE Benutzerhandbuch, 9 paginas
POWXG9451 PRESSURE PUMP 800W 25L DE Manual de usuario   Powerplus POWXG9451 PRESSURE PUMP 800W 25L DE Benutzerhandbuch, 9 paginas
POW67930 GARDEN PUMP 800W RU Manual de usuario   Инструкция по эксплуатации Powerplus POW67930 GARDEN PUMP 800W RU, 9 paginas
POW67912 SUBMERSIBLE PUMP 400W SS ES Manual de usuario   Powerplus POW67912 SUBMERSIBLE PUMP 400W SS ES Manual del usuario, 8 paginas
POW67920 SUBMERSIBLE PUMP 750W ES Manual de usuario   Powerplus POW67920 SUBMERSIBLE PUMP 750W ES Manual del usuario, 9 paginas
POW67935 PR ESSURE PUMP 1000W 20L ES Manual de usuario   Powerplus POW67935 PR ESSURE PUMP 1000W 20L ES Manual del usuario, 11 paginas
POW67900 SUBMERSIBLE PUMP 200W ES Manual de usuario   Powerplus POW67900 SUBMERSIBLE PUMP 200W ES Manual del usuario, 8 paginas
POW67902 SUBMERSIBLE PUMP 250W ES Manual de usuario   Powerplus POW67902 SUBMERSIBLE PUMP 250W ES Manual del usuario, 8 paginas
POW67904 SUBMERSIBLE PUMP 400W ES Manual de usuario   Powerplus POW67904 SUBMERSIBLE PUMP 400W ES Manual del usuario, 8 paginas
POW67906 SUBMERSIBLE PUMP 750W ES Manual de usuario   Powerplus POW67906 SUBMERSIBLE PUMP 750W ES Manual del usuario, 8 paginas
POW67912 SUBMERSIBLE PUMP 400W SS ES Manual de usuario   Powerplus POW67912 SUBMERSIBLE PUMP 400W SS ES Manual del usuario, 9 paginas
POW67915 SUBMERSIBLE PUMP 900W SS ES Manual de usuario   Powerplus POW67915 SUBMERSIBLE PUMP 900W SS ES Manual del usuario, 8 paginas
POWXG9417 SUBMERSIBLE PUMP 750W SS +SENSOR RU Manual de usuario   Инструкция по эксплуатации Powerplus POWXG9417 SUBMERSIBLE PUMP 750W SS +SENSOR RU, 8 paginas
POWXG9442 GARDEN PUMP 800W RU Manual de usuario   Инструкция по эксплуатации Powerplus POWXG9442 GARDEN PUMP 800W RU, 11 paginas