200PIN DDR2 400 SO-DIMM
512MB With 64Mx8 CL3
Transcend Information Inc.
5
Absolute Maximum DC Ratings
Parameter Symbol Value Unit Notes
Voltage on VDD relative to Vss VDD -1.0 ~ 2.3 V 1
Voltage on VDDQ pin relative to Vss VDDQ -0.5 ~ 2.3 V 1
Voltage on VDDL pin relative to Vss VDDL -0.5 ~ 2.3 V 1
Voltage on any pin relative to Vss VIN, VOUT -0.5 ~ 2.3 V 1
Storage temperature TSTG -55~+100 °C 1,2
Operating Temperature TA 0 ~ 70 °C
1.Stress greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the
stress rating only and functional operation of the device at these or any other conditions above those indicated
in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions
for extended periods may affect reliability.
Note:
2.Storage Temperature is the case surface temperature on the center/top side of the DRAM. For the
measurement conditions, please refer to JESD51-2 standard.
AC & DC Operating Conditions
Recommended DC operating conditions (SSTL –1.8)
Rating
Parameter Symbol
Min Typ. Max
Unit Notes
Supply voltage VDD 1.7 1.8 1.9 V
Supply voltage for DLL VDDL 1.7 1.8 1.9 V 4
Supply voltage for Output VDDQ 1.7 1.8 1.9 V 4
I/O Reference voltage VREF 0.49*VDDQ 0.50*VDDQ 0.51*VDDQ V 1,2
I/O Termination voltage VTT VREF-0.04 VREF VREF+0.04 V 3
DC Input logic high VIH(DC) VREF+0.125 - VDDQ+0.3 V
DC Input logic low VIL(DC) -0.3 - VREF-0.125 V
There is no specific device VDD supply voltage requirement for SSTL-1.8 compliance. However under all
conditions VDDQ must be less than or equal to VDD.
1.The value of VREF may be selected by the user to provide optimum noise margin in the system. Typically the
value of VREF is expected to be about 0.5 x VDDQ of the transmitting device and VREF is expected to track
variations in VDDQ.
2.Peak to peak AC noise on VREF may not exceed +/-2% VREF (DC).
3.VTT of transmitting device must track VREF of receiving device.
Note:
4.AC parameters are measured with VDD, VDDQ and VDDDL tied together.
Operating Temperature Condition
Parameter Symbol Rating Unit Note
Operating Temperature TOPER 0 to 95 °C 1,2,3
1.Operating Temperature is the case surface temperature on the center/top side of the DRAM. For the
measurement conditions, please refer to JESD51.2 standard.
2. At 0 - 85°C, operation temperature range are the temperature which all DRAM specification will be supported.
Note:
3. At 85 - 95 °C operation temperature range, doubling refresh commands in frequency to a 32ms period
( tREFI=3.9 us ) is required, and to enter to self refresh mode at this temperature range, an EMRS command is
required to change internal refresh rate.
Przeglądanie stron 4
1 2 3 4 5 6 7 8 9 10 11

Komentarze do niniejszej Instrukcji

Brak uwag

Kontron CP342 manuales

Manuales del propietario y guías del usuario para Hardware Kontron CP342.
Ofrecemos 1 manuales en pdf Kontron CP342 para descargar gratis por tipos de documentos: Manual de usuario






Más productos y manuales para Hardware Kontron

Modelos Tipo de documento
CP930 Manual de usuario   Kontron CP930 User Manual, 46 paginas
CP932 Manual de usuario   Kontron CP932 User Manual, 52 paginas
CP346 Manual de usuario   Kontron CP346 User Manual, 72 paginas
CP384 Manual de usuario   Kontron CP384 User Manual, 66 paginas
CP383 Manual de usuario   Kontron CP383 User Manual, 74 paginas
CP382 Manual de usuario   Kontron CP382 User Manual, 58 paginas
CP381 Manual de usuario   Kontron CP381 User Manual [fr] , 60 paginas
CP372 Manual de usuario   Kontron CP372 User Manual, 64 paginas
CP371 Manual de usuario   Kontron CP371 User Manual, 60 paginas
CP353 Manual de usuario    Kontron CP353 Benutzerhandbuch, 27 paginas
CP-RIO3-04S Manual de usuario   Kontron CP-RIO3-04S User Manual, 38 paginas
CP390 Manual de usuario   Kontron CP390 User Manual, 36 paginas
CPS3410 Manual de usuario   Kontron CPS3410 User Manual [fr] , 9 paginas
CPS3402 Manual de usuario   Kontron CPS3402 User Manual, 9 paginas
CPS3105 Manual de usuario   Kontron CPS3105 User Manual, 9 paginas
CPS3101 Manual de usuario   Kontron CPS3101 User Manual, 9 paginas
CPS3003-SA Manual de usuario   Kontron CPS3003-SA User Manual, 19 paginas
PB-SIO4 Manual de usuario   Kontron PB-SIO4 User Manual, 34 paginas
PB-SIO4A Manual de usuario   Kontron PB-SIO4A User Manual, 34 paginas
PB-DOUT8 Manual de usuario   Kontron PB-DOUT8 User Manual, 34 paginas